Studies have shown that for each grade the ISO code is lowered, the life of a hydraulic component can be doubled or tripled!

As shown in the chart, new oil is rated at approximately 18/15. With the Kleenoil Filtration System, oil will attain an ISO 4406 standard of less than 14/11.

Table of ISO 4406 Particle Counts

ISO Code Number of Particles per 1ml < 5 Micron in Size Number of Particles per 1ml > 15 Micron in Size
23/20
23/19
23/18
23/17
40,000 – 80,000
40,000 – 80,000
40,000 – 80,000
40,000 – 80,000
5,120 – 10,400
2,560 – 5,200
1,280 – 2,600
640 – 1,300
22/19
22/18
22/17
22/16
20,000 – 40,000
20,000 – 40,000
20,000 – 40,000
20,000 – 40,000
2,560 – 5,200
1,280 – 2,600
640 – 1,300
320 – 640
21/18
21/17
21/16
21/15
10,000 – 20,000
10,000 – 20,000
10,000 – 20,000
10,000 – 20,000
1,280 – 2,600
640 – 1,300
320 – 640
160 – 320
20/17
20/16
20/15
20/14
5,000 – 10,000
5,000 – 10,000
5,000 – 10,000
5,000 – 10,000
640 – 1,300
320 – 640
160 – 320
80 – 160
19/16
19/15
19/14
19/13
2,500 – 5,000
2,500 – 5,000
2,500 – 5,000
2,500 – 5,000
320 – 640
160 – 320
80 – 160
40 – 80
Approximate New Oil 18/15
18/14
18/13
18/12
1,300 – 2,500
1,300 – 2,500
1,300 – 2,500
1,300 – 2,500
160 – 320
80 – 160
40 – 80
20 – 40
17/14
17/13
17/12
17/11
640 – 1,300
640 – 1,300
640 – 1,300
640 – 1,300
80 – 160
40 – 80
20 – 40
10 – 20
16/13
16/12
16/11
16/10
320 – 640
320 – 640
320 – 640
320 – 640
40 – 80
20 – 40
10 – 20
5 – 10
15/12
15/11
15/10
15/9
160 – 320
160 – 320
160 – 320
160 – 320
20 – 40
10 – 20
5 – 10
2.5 – 5
Kleenoil Bypass Filter Range 14/11
14/10
14/9
14/8
80 – 160
80 – 160
80 – 160
80 – 160
10 – 20
5 – 10
2.5 – 5
1.3 – 2.5
13/10
13/9
13/8
13/7
40 – 80
40 – 80
40 – 80
40 – 80
5 – 10
2.5 – 5
1.3 – 2.5
0.6 – 1.3
12/9
12/8
12/7
12/6
20 – 40
20 – 40
20 – 40
20 – 40
2.5 – 5
1.3 – 2.5
0.6 – 1.3
0.3 – 0.6